Product Testing - Fire
Tests have been conducted by CSIRO Australia and BRANZ.
Report
Description
Thickness
FRL
BRANZ FR 3754
Bare 78mm Speedpanel wall to 3.0 metre spans
78mm
-/240/120
CSIRO FCO 2619
Bare 78mm Speedpanel wall to 4.5 metre spans
78mm
-/120/120
-
On fire consulting design advice, 6.0 metre high Speedpanel
78mm
-/120/120
CSIRO FCO 1762
2 x 78mm Speedpanel walls with 50mm air cavity
204mm
-/240/240
* Note that the height of the wall may affect the fire rating of the wall system and
require the assessment by a fire engineer.
Fire Test Reports
FR-3754 Fire Resistance of a Vertical Panel Wall
Conducted by: BRANZ, June 2007
FCO-2619 Likely fire resistance of modified wall system
Conducted by: CSIRO Australia, April 2008
FCO-1762 Likely fire resistance of modified wall system
Conducted by: CSIRO Australia, February 2006
Cert 784: Speedpanel with 10mm standard plasterboard
Conducted by: CSIRO Australia, April 1998
Cert 785: Speedpanel with 13mm fire rated plasterboard
Conducted by: CSIRO Australia, April 1998
FCO-1597 Likely fire resistance for modified wall system
Conducted by: CSIRO Australia, February 2004
FCO-2368 Likely fire resistance for modified wall system
Conducted by: CSIRO Australia, October 2004
Speedpanel diagram for FCO-2368
Conducted by: CSIRO Australia, N/A
Legend:
Downloadable PDF document
Report available upon request
SPEEDPANEL
89-91 CANTERBURY ROAD, KILSYTH, VIC., 3137
Phone: (03) 9724 6888 Fax: (03) 9724 6889
Home
|
Company Information
|
Product Literature
|
News
|
Links
|
Contact
Wall Systems
|
Order
|
Installation
|
Industry Tests
|
Product Applications
|
Media Gallery
Copyright © 2003 - 2009 Speedpanel. All rights reserved.