Wall Systems
Each wall system profiled below is configured to meet particular design parameters
for fire rating and acoustic performance while at the same time achieving system weight and wall thickness targets. For each design there is a cross-section diagram, composite description, test report identification and performance details.
At Speedpanel, we understand your building project is unique and are happy to discuss options that would best suit your needs.
 |
System 1A - Rw 40 - Bare Wall System |
Acoustic test report: 121I/837/PD
Fire rating: -/240/120 up to 3m spans Thickness: 78mm |
| |
System 1A composition: - 78mm thick 435 Kg per m³ density bare Speedpanel.
|
| |
 |
System 18A - Rw 62 - Acoustic w/ bulkhead |
Acoustic test report: 121I/09-089/PD
Fire rating: -/240/120 up to 3m spans Thickness: 250mm |
| |
System 18A composition:
- 13mm standard plasterboard
- 64mm metal stud
- 50mm x 14Kg fibreglass insulation
- 50mm gap
- 600Kg Speedpanel
- 28mm furring channel
- 13mm plasterboard |
| |
 |
System 18C - Rw 60 - Acoustic w/ bulkhead |
Acoustic test report: 121I/09-090B/PD
Fire rating: -/240/120 up to 3m spans Thickness: 250mm |
| |
System 18C composition:
- 3GPO each side of wall
- 1 light switch each side of wall (unbacked)
- 200mm x 200mm hole cut into bulkhead
- 13mm standard plasterboard
- 64mm metal stud
- 50mm x 14Kg fibreglass insulation
- 50mm gap
- 600Kg Speedpanel
- 28mm furring channel
- 13mm plasterboard |
| |
 |
System 17B - Rw 58 - Acoustic |
Acoustic test report: 121I/08-152
Fire rating: -/240/120 up to 3m spans Thickness: 175mm |
| |
System 17B composition:
- 78mm thick 600 Kg per m³ density bare Speedpanel
- 20mm air cavity
- 64mm steel stud frame
- AAB14-75 (14Kg x 75mm) acoustic insulation
- 13mm plasterboard |
| |
More Wall Systems